AOR AR5000 Manuale Utente Pagina 7

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 12
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 6
Specification
Frequency Range: 530 kHz to 2040 MHz *
(Actual frequency input 100 kHz to 2040 MHz,
performance between 100 kHz to 530 kHz is
not guaranteed).
Receive Modes: WFM, NFM, SFM, WAM, AM, NAM, USB, LSB, CW
Sensitivity: 500 kHz ~ 2.0 MHz
AM: 3.50 µV (10dB S/N)
2.0 MHz ~ 30 MHz
SSB: 1.50 µV (10dB S/N)
AM: 2.50 µV (10dB S/N)
30 MHz ~ 470 MHz
SSB: 0.30 µV (10dB S/N)
AM: 0.70 µV (10dB S/N)
NFM: 0.35 µV (12dB SINAD)
WFM: 1.00 µV (12dB SINAD)
470 MHz ~ 1 GHz
NFM: 0.50 µV (12dB SINAD)
WFM: 1.50 µV (12dB SINAD)
1.0 GHz ~ 1.3 GHz
NFM: 1.00 µV (12dB SINAD)
1.3 GHz ~ 2.039 GHz
NFM: 2.50 µV (12dB SINAD)
Selectivity: SSB/NAM 3kHz (-6dB), 9kHz (-60dB)
AM/SFM 9kHz (-6dB), 20kHz (-40dB)
WAM/NFM 12kHz (-6dB), 25kHz (-40dB)
WFM 150kHz (-3dB), 380kHz (-20dB)
Power Consumption: 190mA (nominal), 145mA (stand by), 25mA (power save).
4 x AA internal cells
or 12V d.c. external supply
Dimensions: 61(W) x 143(H) x 39(D) mm
Weight: 217g (311g inc. NiCads, 356g inc. NiCads & aerial)
Memory channels: 1,000 (20 banks)
Select scan channels: 50
Priority channels: 1
Search banks: 40
PASS channels: 50 per search bank + 50 for VFO search
Scan/Search Rate: Maximum 37.42 steps per second
With auto-mode off, 10 kHz step, * lock time 2mS,
* Squelch wait 15mS. (*this value is preset and varies
depending upon band and step, squelch wait times of 15mS,
25mS and 30mSare employed).
Optional accessories
Slot cards:
Five slot cards are available, only one may be fitted at a time.
VI8200 Voice inverter (analogue) in 157 steps.
CT8200 CTCSS squelch & search.
TE8200 Tone eliminator in 256 steps.
RU8200 Chip based recording and playback, 20 seconds
approx.
EM8200 External extended memory, backup 4,000
memories, 160 search banks (can hold as much
data as 4 x AR8200 SERIES-2).
Leads:
Three leads are available for use with the option socket.
CR8200 Tape recording lead.
CO8200 Data clone lead.
CC8200 Computer control lead with level shift
(available with imperial (PC98) & metric
(DOSV) screws) and supplied with RS232
protocol listing in PDF format and PC software.
Aerials:
There are many suitable aerials available on the market, these
include.
DA900 VHF/UHF flexible whip 245mm in length.
MA500 VHF/UHF whip aerial on magneticbase with 4m
of coaxial cable. Base is 85mm in diameter, total
height is 720mm. Coverage is 25 to 1300 MHz.
DA3000 16 element discone aerial with 15 of coax.
Coverage is 30 MHz to 2 GHz.
SA7000 Passive twin element wide band aerial with 15m
of coax. Coverage is 30 kHz to 2 GHz.
LA320 Desktop loop aerial 1.6 MHz to 15 MHz.
Optional elements available for LW & MW.
Supplied with BNC lead.
ABF125 VHF airband filter for increased adjacent channel
selectivity.
Case: SC8200 Leatherette protective case.
Tuning is accomplished via a variety of controls including a side panel indented main tuning dial, arrow keys and keypad.
A larger than average back lit LCD with contrast control provides operational data with the ability to add 12 character text
comments to each memory channel, memory bank and search bank, a text search feature simplifies identification and recall
of stored information. Many text prompts aid operation making programming of search banks etc straight forward.
Two frequencies may be displayed along with operating legends and high resolution signal meter and multi-function band
scope. The band scope provides adjustable span width from 10 MHz to 100 kHz , you can move the marker, operate peak
hold, transfer the marker frequency to VFO and save trace for later recall. The stylish black cabinet has a quality feel with an
excellent rear-illuminated keypad with a hard wearing finish.
Flexible dynamic memory bank layout is provided (memory banks may be varied in size between 10 and 90 channels each
i.e. bank ‘A’ 80 channels / bank ‘a’ 20 channels with bank ‘B’ 40 channels / bank ‘b’ 60 channels etc
). A total of 1,000
memories are provided in 20 memory banks, lockout, select scan, priority and auto store are also provided. In addition 40
search banks are provided with 50 pass channels per search bank and a further 50 for VFO search lockout. Comprehensive
edit, move, swap and delete facilities are provided, it is possible to move whole memory & search banks. Scan & search
rates provide a maximum of approximately 37 increments per second. Flash-ROM memory storage ensures that data is
automatically saved without the need for a backup battery or capacitor.
Computer control is available via a metallic side mounted robust connector and optional lead, an extensive RS232 command
list is supported. A FREE software package is available as a download from the AOR web sites.
The AR8200 SERIES-2 is powered from 4 x AA internally fitted high capacity NiCad cells (supplied), dry cells may be
used. External power may also be connected to the charge socket for extended periods of operation (9 - 16V d.c.).
‘As if this was not enough’, optional internal SLOT CARDS (which fit into the AR8200 SERIES-2 base) extend the
capabilities even further: l
Memory slot card
(increase storage to 4,000 memories, 160 search banks). l
CTCSS slot
card
squelch & search. l
Record chip slot card
(records up to 20 seconds of audio). l
Tone eliminator slot card,
l
Voice inverter card.
All this in a cabinet which weighs just 217g (excl. NiCads & aerial, 311g with NiCads fitted) with
dimensions of 61(W) x 143(H) x 39(D) mm (excl. projections).